Morphologic changes in the nodular goitre induced by the LigaSure high frequency current generator

dc.contributor.author Yermakova, Tetyana
dc.date.accessioned 2025-05-13T09:04:50Z
dc.date.available 2025-05-13T09:04:50Z
dc.date.issued 2016-01-13
dc.description.abstract Summary: Today, surgical dissection and tissue coagulation with both monopolar and bipolar coagulation as well as LigaSure high frequency current generator (HFCG) are the surgical modalities of choice in the treatment of thyroid pathology. However, the question of the high frequency current effect on the morphofunctional condition of the post hemithyroidectomic parenchyma is still disputable. The goal of the research is a thorough histological analysis of the surgically removed thyroid tissue specimen.The nodular goitre of 50 patients was subject to the histological study. The surgery was performed with the LigaSure HFCG. The 1.0x0.5 thyroid tissue specimens were excised from three areas. Hemithyroidectomy lasted for 40-50 min and thyroidectomy – 120 ± 4.2 min. In both procedures, the blood loss was within 70-150 ml, no haemorrhage being observed in both intra-and postoperative period.The zonal effect of high frequency current on the thyroid structure was determined morphologically, namely coagulation necrosis in the site of direct action, intensified secretory response of the thyroid tissue to the extremal factor in the perifocal area, and typical structure was determined morphologically, namely coagulation necrosis in the site of direct action, intensified secretory response of the thyroid tissue to the extremal factor in the perifocal area, and typical structure of the nodular goitre with the signs of impaired microcirculation in the remote area. Morphologic changes of the thyroid gland, with high frequency current used as a dissector, are distance-dependent. en
dc.identifier.citation Yermakova T. (2015), Morphologic changes in the nodular goitre induced by the LigaSure high frequency current generator.
dc.identifier.issn 2353-6942
dc.identifier.uri https://hdl.handle.net/20.500.13044/2181
dc.language.iso en
dc.publisher Państwowa Szkoła Wyższa im. Papieża Jana Pawła II w Białej Podlaskiej
dc.subject nodular goitre en
dc.subject thyroid gland en
dc.subject Liga Sure en
dc.title Morphologic changes in the nodular goitre induced by the LigaSure high frequency current generator
dc.type Article
Pliki
Oryginalny pakiet
Aktualna strona 1 - 1 z 1
Miniatura obrazu
Nazwa:
MORPHOLOGIC CHANGES IN THE NODULAR GOITRE INDUCED BY THE LIGASURE HIGH FREQUENCY CURRENT GENERATOR.pdf
Rozmiar:
1.86 MB
Format:
Adobe Portable Document Format
Opis:
Pakiet licencji
Aktualna strona 1 - 1 z 1
Brak dostępnej miniatury
Nazwa:
license.txt
Rozmiar:
652 B
Format:
Item-specific license agreed to upon submission
Opis: